CMS 8000 Multi Parameter Patient Monitor

CMS 8000 Multi Parameter Patient Monitor

Regular price Rs. 49,499.00
Regular price Sale price Rs. 49,499.00
Sale Sold out

Availability : In Stock

For Bulk Enquiry
Click on WhatsApp icon and write product Name with Quantity.
WhatsApp
WhatsApp or Call
098141-81255

Shipping & Returns

Free Shipping available on all orders!
We ship all India orders within 5-6 days.

Bulk Enquiries

WhatsApp or Call 9814262255 Click on WhatsApp icon and write product code with quantity.

View full details

Main Features

  • 12.1” Color TFT LCD display with waveforms upto 8 Channels.
  • Portable, streamline handle design.
  • Monitor measures from Adult and Neonates.
  • Graphic and tabular trend for 96 hours for all parameters.
  • Multi-Screen format.
  • Audible and Visual Alarms with adjustable alarm ranges.
  • Powerful data management and storage capacity.
  • Manual or Automatic NIBP measuring.
  • With 500unit memory.
  • Rechargeable Battery Backup.
  • Weight : 4.5 Kg. approx.


Respiration

  • Method : RA-LL impedance
  • Measurement Range : Adult : 0-120rpm, Paediatric Neonatal : 0-150rpm
  • Apnea Alarm : Yes


Temperature

  • Resolution : 0.1° C
  • Channels : Dual – Channel
  • Measurement Range : 0-50° C


IBP (Upgradable)

  • Channel : 2 Channels
  • Pressure Transducer : Sensitivity : 5 (mV V mmHg)
  • Transducer Site : ART, PA, CVP, RAP, LAP, ICP
  • Alarm Range : -10~300mmHg


ECG

  • 5-lead or 12-lead selectable
  • Input : 5-lead : RA; LA; RL; LL; V Or R; L; F; C
  • Lead Selection : I; II; III; avR; avL; avF; Vx; CAL
  • Gain Selection : x0.25, x0.5, x1, x2, auto
  • Sweep Speed : 12.5mm/s, 25mm/s, 50mm/s
  • Accuracy : +1bpm or +1%, whichever is greater
  • Protection : Withstand 4000V AC/50Hz Voltage in isolation against electrosurgical and defibrillation
  • Calibration Signal : 1mV=5%
  • Operation Modes : Diagnostic, Monitor, Surgery
  • Heart Rate Range : Adult : 15-300bpm Paediatric / Neonatal : 15-350bpm
  • Measurement Range : -2.0mV ~ 2.0mV
  • S-T Detection : Yes, Audible and Visual Alarm, Alarm events recallable


NIBP

  • Method : Oscillometry
  • Operation Modes : Manual Automatics / STAT
  • Measurement Unit : mmHg / KPa selectable
  • Measurement types : Systolic, Diastolic, Mean
  • Measurement Range : Adult : 10-270mmHg
  • Over-Pressure Protection : Yes
  • Resolution : 1mmHg
  • Accuracy : The mean error shall be less than ±5mmHg, the standard deviation shall be less than ±8mmHg
  • Alarm : Systolic, Diastolic, Mean


SPO2

  • Measurement Range : 0-100%
  • Accuracy :±2% (70~100%); 0~69% Unspecified
  • Alarm Range : 0-100%